ML51/ML54/ML56
Sep. 01, 2020
Page
120
of 719
Rev 2.00
ML
51
/ML
54
/ML
5
6 S
E
RI
E
S
TECHNI
CA
L
RE
F
E
R
E
NC
E
M
A
NU
A
L
ML51/M
L54
/M
L56
Series
Tec
hnical Reference
Manual
XLTCON
– XLT Clock Control (TA Protected)
Register
SFR Address
Reset Value
XLTCON
85H, Page 1, TA protected
0111_0111b
7
6
5
4
3
2
1
0
HSCH
HXSG[2:0]
-
-
LXSG[1:0]
R/W
R/W
-
-
R/W
Bit
Name
Description
[7]
HSCH
HXT Schmitt Trigger Select
0 = disable
1 = enable
[6:4]
HXSG[2:0]
HXT Gain Value Select
000 = L0 mode (smallest value)
001 = L1 mode
010 = L2 mode
011 = L3 mode
100 = L4 mode
101 = L5 mode
110 = L6 mode
111 = L7 mode (largest value)
[3:2]
-
Reserved
[1:0]
LXSG[1:0]
LXT Gain Value Select
00 = L0 mode (smallest value)
01 = L1 mode
10 = L2 mode
11 = L3 mode (largest value)