AINDIDS0
– ADC Channel Digital Input Disconnect
Register
SFR Address
Reset Value
AINDIDS0
CEH, Page 1
0000_0000 b
7
6
5
4
3
2
1
0
AIN7DIDS
AIN6DIDS
AIN5DIDS
AIN4DIDS
AIN3DIDS
AIN2DIDS
AIN1DIDS
AIN0DIDS
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Bit
Name
Description
[7:0]
AINnDIDS
ADC Channel Digital Input Disable
0 = Enabled digital input at ADC channel n.
1 = Disabled digital input at ADC channel n . ADC channel n is read always 0.