— 11-4 —
u
Sequence Code
Command
: (HS), (AD), (AR), (ID), (IR)
Condition setting
: *, &
l
Add a sequence code to the command to execute the next channel continuously. In this case, you do
not have to select a channel externally.
Table 11-2
Sequence code
IPOS output
Execution of the next channel
* : asterisk
Yes
Executes next program continuously after positioning is over.
& : ampersand
Yes
Stops after indexing, then waits for RUN command.
*Program example
:CH0
IR500*
:CH1
IR1000&
Figure 11-4
IR500
∗
IR1000&
CH0
PRG0 ~ 3
RUN input
Program Operation
IPOS output
(FW
≠
0)
CH1
0
u
Changing Sequence Code
Condition setting
: OE
l
OEseq changes the sequence code presently set.
* Program example
:CH0----------------------
Declare the channel whose sequence code is to be changed.
AR9000&
CV0.5
?OE* ---------------------
input
ENT
E
∗
O
?
:TC0 ----------------------
Check the new data programmed in this channel.
AR9000* ---------------
The sequence code has changed from “&” to “
∗
”.
CV0.5
:
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com