— 8-7 —
7)
When rotational angle (ID) 9000 (90 degrees) is feasible, input “OK”.
IN10,IS0.5,FW1.0
ID9000/OK
?OK
:_
K
ENT
O
The motor starts the cycles as soon as “OK” is logged in.
(Firstly the Motor rotates clockwise (CW). )
l
For changing rotational angle (ID) while “?” prompt is displayed, input desired ID without inputting
“OK.”
8)
To terminate the demonstration program input the command to display its menu screen. Press ENT
key after “?” to get out the demonstration program.
◊
Example for rotational angle: 30° (degree)
?ID3000
IN10,IS0.5,FW1.0
ID3000/OK
?_
D
3
<
I
0
?
0
?
ENT
0
?
9)
When the tria l running is completed, type
:MS
:_
S
ENT
M
to stop the Motor.
l
If the Motor is operating satisfactly, complete the trial running.
l
When the Motor operation is not stable, try further adjustment in chapter 8.2.5 and 8.3.
l
If you want to get out from the demonstration program, press the enter key after “? .”