14.2.4. Alarms Related to Control
14.2.4.1. Memory Error
[Output]
DRDY: Open
[TA]
E0 > Memory Error
[LED]
E0
[Motion Condition]
Servo-OFF
Table 14-10: Cause and Remedy: Memory error
Cause
Remedy
(1) Parameters stored in the memory have been
rewritten by noise or other cause.
•
Initialize the memory then reenter the parameters.
(Refer to “12. Command and Parameter.”)
(2) Faulty PCB.
(When the memory is not functioning after
initialized.)
•
Replace Driver Unit.
◊
Standard ESA Driver --------------------[Appendix 4]
◊
Command “SI” (RS-232C communication) initializes the memory. After initializing, some
parameters are reset to shipping set. Resetting parameters to actual use condition are
necessary.
14.2.4.2. EEPROM Error
[Output]
DRDY: Open
[TA]
E2 > EEPROM Error
[LED]
E2
[Motor Condition]
Servo-OFF
Table 14-11: Cause and Remedy: EEPROM error
Cause
Remedy
(1) Faulty EEPROM of control circuit.
•
Turn the power on again.
•
Replace Driver Unit.
◊
Standard ESA Driver --------------------[Appendix 4]
14.2.4.3. System Error
[Output]
DRDY: Open
[TA]
E7>System Error
[LED]
E7
[Motor Condition]
Servo-OFF
Table 14-12: Cause and Remedy: System Error
Cause
Remedy
(1) Faulty ROM on PCB.
(2) Faulty EEPROM on PVB.
•
Replace Driver Unit.
◊
Standard ESA Driver --------------------[Appendix 4]