— A-4 —
[Example] Verify the start command of channel program “RUN” is on.
1)
Confirm that the displa y of Handy Terminal indicates the colon ( : ).
(If the display does not show the colon press ENT key once.)
:_
2)
:IO2_
O
2
#
I
3)
:IO2/RP_
R
P
/
4)
Press ENT key for execution. Indication starts immediately after the input.
:IO2/RP
0000001000/000
ENT
RUN
5)
Press BS key to discontinue the readout. Otherwise you cannot enter next command.
:IO2/RP
0000001000/000
:_
BS
[Discription]
l
Above example shows that the readout of RUN input is “1,” which indicates “RUN” input is on.
◊
In case of the above example, the status of Input / Output signal are monitored and
indicated until BS key is pressed.
◊
On and Off of the Input / Output signals will be followed during the readout by changing
in “1” to “0” or the other way.
◊
However, if inputting / RP is omitted in procedure 3) in the above example, I/O status will
be indicated only once just after ENT key is pressed.