— 9-17 —
[Example] Verify the Programmable Indexer start command “RUN” is ON.
1)
Confirm that the display of Handy Terminal shows the colon “:.”
(If the colon does not appear on the display press ENT key once. )
:_
2)
Input the command to read out state of Inputs/Outputs.
:IO2_
O
2
$
I
3)
Add /RP for repetitious readout.
:IO2/RP_
/
R
P
4)
Press the enter key to execute.
Readout starts immediately after the input.
ABCDEFGHIJKLMN
0000001000/000
ENT
RUN
5)
Press the back space key to discontinue read out. If it is not pressed, read out will be
repeated and the next command can not be accepted.
ABCDEFGHIJKLMN
0000001000/000
BS
RUN
l
Above example shows that readout of RUN input is “1”, which indicates “RUN” input is ON.
[Reference]
◊
Readout follows the changes of signal status while repeating reading-out.
(Signals ON and OFF are followed by 1 and 0 in the display.)
◊
If the option code “/RP” is not entered, the read-out at the moment will be displayed for
only once.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com