— A-10 —
2 Initialize Driver Unit.
1)
Connect the Handy Terminal FHT11 to CN1 connector of the Driver Unit.
↓
2)
Turn on the control power only.
↓
3)
Input the password. When the colon “:” is displayed,
Press
K
N
S
/
SP
N
ENT
O
.
↓
4)
Driver Unit echoes back “NSK ON.”
↓
5)
Input “SI/SY” command.
Press
S
I
/
S
Y
.
↓
6)
Driver Unit echoes back “INITIALIZE.” A colon “:” will be displayed to indicate completion of
initializing.
3 Input the noted parameter settings and channel programs.
1)
Firstly set “PA” parameter.
l
Input the password.
Press
K
N
S
/
SP
N
ENT
O
.
Driver Unit echoes back “NSK ON.”
↓
2)
Press
∗
A
∗
P
ENT
(** must be the same data as noted.)
↓
3)
Set other parameters and programs accordingly.
↓
4)
Make sure that all parameters and programs are set properly.
↓
Monitor the settings with “TS0” and “TC data” commands.
↓
5)
Turn off the power.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com