— 9-5 —
9.1.5.2. Software Over-travel Limit Switch
Notes to be taken in over-travel limit setting
Caution : • The over-travel area should be 1000 [pulses] or wider. When the over-travel
area is too narrow the Motor may turn through the “off-limits” area.
• Set the over-travel limits with ample margin, giving consideration to the
overshoot of the mechanism controlled by the Motor.
• When “off-limits” area is specified by the software over travel limit, the Motor
rotates to the direction to avoid off-limit area regardless of moving distance.
(Commands AD and AR is disregarded, even it is set.)
l
This function becomes valid after the Home position is determined by Home Return or AZ
command.
l
Use the OTP and OTM commands to set the over-travel limit values.
<Operation> Setting by teaching
1)
Turn off the Motor servo.
:MO
:_
O
ENT
M
2)
Move the Motor’s rotor manually to a point to be the over-travel limit on the plus side.
3)
Input the password.
:MO
:/NSK ON
NSK ON
:_
N
S
/
SP
K
N
ENT
O
4)
Register the present position as the over-travel limit on the plus side. The registered
over-travel limit value appears on the display.
:OTP/ST
OTP123456
OTM0
:_
T
P
O
S
T
/
ENT
5)
Move the Motor’s rotor manually to a point to be the over-travel limit on the minus side.
6)
Input the password.
:MO
:/NSK ON
NSK ON
:_
N
S
/
SP
K
N
ENT
O
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com