— 5-18 —
5.4. CN4 : Motor Cable Connector
l
Since the Motor cable supplied with the Megatorque Motor System should always be used, you
need only plug the Motor cable connector into CN4. Knowledge of the pin assignment or signal
name is not necessary. This section is offered for reference.
Caution : • Do not change the cable length.
• Do not use other connector between the Motor cable and CN4.
Danger : • Be careful for orientation of the connector when inserting it. The connector is
a self-lock type. Insert the connector to its bottom, otherwise it will not lock.
• Never insert/remove the CN4 connector with the Driver Unit power turned
on.
• A high voltage is applied to this connector after the power is turned on. Be
very careful not to cause short-circuit.
Table 5-19
Driver Unit connector
AMP 172039-1
Mating connector type *
(user device side)
AMP 172495-1
Mating connector shell type *
(user device side)
AMP 172774-1
* Provided with the cable.
5.4.1. CN4 Pin-out
Figure 5-18 : CN4 Pin-out
7
6
4
3
2
1
5
C+
C-
E
A+
A-
B+
B-
5.4.2. CN4 Signal List
Table 5-20 : Signal Name and Function
Pin
Signal Name
Function
1
A+
Motor winding phase A (+)
2
A-
Motor winding phase A (-)
3
B+
Motor winding phase B (+)
4
B-
Motor winding phase B (-)
5
C+
Motor winding phase C (+)
6
C-
Motor winding phase C (-)
7
E
Motor grounding wire