— 4-28 —
4.2.4. Jumper
l
Jumper (JP1) is for selecting output format of øZ position feedback signal.
l
Jumper is inside of the Driver Unit. When setting Jumper, remove the side cover of the Driver Unit.
Follow the procedure in Appendix 4 : How to Replace ESA25 Driver Unit.
l
Figure 4-14 indicates the Jumper location.
Figure 4-21
Driver Unit front panel
OC
LD
LED
JP1
CN3
CN2
CN1
Table 4-13 : Jumper setting.
Setting
øZ output format
LD-Out short
Line driver (Shipping set)
OC-Out short
Open collector