![Unidrive M70 Series Installation Sheet Download Page 1](http://html2.mh-extra.com/html/unidrive/m70-series/m70-series_installation-sheet_3748823001.webp)
1
0478-0023-02
1 Safety information
2 Introduction
This document covers through-panel mounting instructions for Unidrive
M600 / M70X, F300, H300, E200 & E300 Size 4 drives. The standard
drive is rated to IP20 pollution degree 2 (dry, non-conductive
contamination only, NEMA 1), however it is possible to configure the
device to achieve IP65 rating (NEMA 12). This is done by sealing the
heat sink vent at the rear of the heatsink by installing the high IP insert
as illustrated in Figure 3-1. Some current derating is required and
reference should be made to the drive’s User Guide for current derating
information.
The following items are supplied in the box:
Table 2-1 Contents of the Box (CT Part Number: 3470-0056-01)
The following items are included in the kit box supplied with the
drive:
Table 2-2 Additional items required
3 Instructions
3.1 Installing the high IP insert
Figure 3-1 Installing the high IP insert
1. To install the high IP insert, firstly place a flat head screwdriver into
the slot highlighted (1).
2. Pull the hinged baffle up to expose the ventilation hole, install the
high IP insert into the ventilation hole in the heatsink (2).
3. Ensure the high IP insert is securely installed by firmly pressing it
into place (3).
4. Close the hinged baffle as shown (1).
To remove the high IP insert, reverse the above instructions.
Unidrive M600-M70X, F300, H300, E200 & E300
Size 4 Through-panel Mounting Installation Sheet
Follow the instructions
The mechanical and electrical installation instructions must
be adhered to. Any questions or doubt should be referred to
the supplier of the equipment. It is the responsibility of the
owner or user to ensure that the installation of the drive and
any external option unit, and the way in which they are
operated and maintained, comply with the requirements of
the Health and Safety at Work Act in the United Kingdom or
applicable legislation and regulations and codes of practice in
the country in which the equipment is used.
Competence of the installer
The drive must be installed by professional assemblers who
are familiar with the requirements for safety and EMC. The
assembler is responsible for ensuring that the end product or
system complies with all the relevant laws in the country
where it is to be used.
Description
Image
Qty
Through panel mounting gasket
x 1
Through panel securing brackets
x 2
High IP insert
x 1
Through panel mounting
instructions sheet
x 1
Description
Image
Qty
Frame 4 mounting brackets
x 2
WARNING
WARNING