12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
12 - 74
(2) Parameter setting
POINT
The following encoder cables are of four-wire type. When using these encoder
cables, set [Pr. PC22 Function selection C-1] to "1 _ _ _" to select the four-wire
type. Incorrect setting results in [AL. 16 Encoder initial communication error 1].
MR-EKCBL30M-L
MR-EKCBL30M-H
MR-EKCBL40M-H
MR-EKCBL50M-H
Assign the following input devices to CN3-6 and CN3-19 pins with [Pr. PD24
Input device selection 7M] and [Pr. PD27 Input device selection 8M].
CN3-6: DI1 (Next station No. selection 2)
CN3-19: SIG (External limit/Rotation direction decision/Automatic speed
selection)
Assign the following output devices to CN3-16 and CN3-22 pins with [Pr. PD31
Output device selection 3] and [Pr. PD32 Output device selection 4].
CN3-16: ZP (Home position return completion)
CN3-22: MEND (Travel completion)
When using this servo in the indexer method, set [Pr. PA01 Operation mode] to "_ _ _ 8" (Positioning
mode (indexer method)). For the indexer method, the servo can be used by changing mainly the basic
setting parameters ([Pr. PA _ _ ]) and positioning control parameters ([Pr. PT _ _ ]).
As necessary, set other parameters.
The following table shows [Pr. PA _ _ ] and [Pr. PT _ _ ] settings required for the indexer method.
Operation mode selection item
Operation mode
Parameter setting
Input device setting
[Pr. PA01]
[Pr. PT45
Home
position
return
types]
[Pr. PT27
Operation
mode
selection]
MD0
(Note)
MD1
(Note)
DI0 to DI7 (Note)
Automatic operation
mode
Automatic operation mode 1
(Rotation direction specifying
indexer)
_ _ _ 8
Off
On
Set any next
station No.
(Refer to section
12.6.2 (2) (c).)
Automatic operation mode 2
(Shortest rotating indexer)
On
On
Manual operation
mode
Station JOG operation
_ _ 0 _
On
Off
Optional
JOG operation
_ _ 1 _
Homing mode
Refer to
section
4.2.4.
Off
Off
Optional
Note. MD0: Operation mode selection 1, MD1: Operation mode selection 2, DI0 to DI7: Next station No. selection 1 to 8
(3) Actual operation
Start actual operation after confirmation of normal operation by test operation and completion of the
corresponding parameter settings.
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...