4. PARAMETERS
4 - 36
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
General
purpose
Communication
CP
PS
CP
PS
PT21
*LNPL
Position
range output
address -
(Lower four
digits)
Set an address decreasing side of the position range output address.
Upper and lower are a set.
Set a range in which POT (Position range) turns on with [Pr. PT19] to [Pr.
PT22].
Set an address in hexadecimal.
Setting address:
Upper four
digits
Lower four
digits
[Pr. PT21]
[Pr. PT22]
The unit can be changed to 10
STM
[μm], 10
(STM-4)
[inch], or [pulse] with the
setting of [Pr. PT01].
Setting range: 00000000h to FFFFFFFFh
0000h
Refer to
Function
column
for unit.
PT22
*LNPH
Position
range output
address -
(Upper four
digits)
0000h
Refer to
Function
column
for unit.
PT26
*TOP2
Function
selection T-2
_ _ _ x Electronic gear fraction clear selection
0: Disabled
1: Enabled
Selecting "Enabled" clears the fraction of the previous command by the
electronic gear at start of the automatic operation.
0h
_ _ x _ Current position/command position display selection
Select the display method for the current position and for the command
position.
0h
Setting
value
Displayed
data
Operation
mode
Status display contents
Current position
Command position
_ _ 0 _
Positioning
display
Auto/
Manual
Display the actual
current position with
the machine home
position set to 0.
Display the command
current position with
the machine home
position set to 0.
_ _ 1 _
Roll feed
display
Automatic Display the actual
current position with
automatic operation
start position set to 0.
Counting starts from
when the start signal
is on and displays the
command current
position up to the
target position.
When stopping, the
command positions
of the point table are
displayed.
Manual
"0" is always
displayed.
_ x _ _ For manufacturer setting
0h
x _ _ _ Touch probe 1 function selection
0: Current position latch function by sensor input
1: Interrupt positioning function by sensor input
0h
PT27
*ODM
Operation
mode
selection
_ _ _ x For manufacturer setting
0h
_ _ x _ Manual operation method selection
0: Station JOG operation
1: JOG operation
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
PT28
*STN
Number of
stations per
rotation
Set the number of stations per rotation (number of indexer stations).
Setting "2" or less will be "2".
Setting range: 0 to 255
8
[Stations]
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...