7. HOW TO USE THE POINT TABLE
7 - 20
(c) Varying-speed operation
By setting the auxiliary function of the point table, the servo motor speed during positioning can be
changed. Point tables are used by the number of the set speed.
1) Absolute value command method ([Pr. PT01] = _ _ _ 0)
Set "1" or "3" to the auxiliary function to execute the positioning at the speed set in the following
point table.
At this time, the position data selected at start is enabled, and the acceleration/deceleration time
constant set in the next and subsequent point tables is disabled.
By setting "1" or "3" to auxiliary functions until point table No. 254, the operation can be
performed at maximum 255 speeds.
Be sure to set "0" or "2" to the auxiliary function of the last point table.
To perform varying-speed operation, be sure to set "0" to the dwell.
Setting "1" or more enables the automatic continuous positioning operation.
The following table shows an example of setting.
Point table No.
Dwell [ms]
(Note 1)
Auxiliary function
Varying-speed operation
1
0
1
Consecutive point table data
2
0
3
3
Disabled
0 (Note 2)
4
0
3
Consecutive point table data
5
0
1
6
Disabled
2 (Note 2)
Note 1. Be sure to set "0".
2. Be sure to set "0" or "2" to the auxiliary function of the last point table of the
consecutive point tables.
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...