9. HOW TO USE JOG MODE
9 - 11
(3) Manual pulse generator multiplication
(a) Setting with object/register
Set bit 4 (C_TP0) of Control DI7 (2D07h) and bit 5 (C_TP1) of Control DI7.
C_TP1 (Manual pulse
generator
multiplication 2)
(Note)
C_TP0 (Manual pulse
generator
multiplication 1)
(Note)
Servo motor rotation multiplication
to manual pulse generator rotation
amount
Travel distance
[mm]
[inch]
[pulse]
0
0
[Pr. PT03] setting enabled
0
1
× 1
0.001
0.0001
1
1
0
× 10
0.01
0.001
10
1
1
× 100
0.1
0.01
100
Note. 0: Off
1: On
(b) Setting with a parameter
Using [Pr. PT03], set the servo motor rotation multiplication to the rotation amount of the manual
pulse generator.
[Pr. PT03] setting
Servo motor rotation multiplication to manual pulse
generator rotation amount
Travel distance
[mm]
[inch]
[pulse]
_ _ 0 _
× 1
0.001
0.0001
1
_ _ 1 _
× 10
0.01
0.001
10
_ _ 2 _
× 100
0.1
0.01
100
(4) Operation
Turning the manual pulse generator rotates the servo motor. For the rotation direction of the servo
motor, refer to (2) in this section. When the manual pulse generator is turned during a JOG operation,
the commands inputted from the manual pulse generator are adjusted by the commands of JOG
operation.
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...