9. HOW TO USE JOG MODE
9 - 9
(b) JOG operation
The following timing chart shows that a JOG operation is performed at a stop of the station No. 0
when servo-on.
Reverse
rotation
0 r/min
Forward
rotation
ON
OFF
ON
OFF
ON
OFF
INP/S_INP
(In-position)
Point actual value
Enabled torque limit value
Controlword bit 4
(Rotation start)
Controlword bit 5
(Direction)
Servo motor speed
Point demand value
1
1 2 3
5
5
0
0
3
Profile velocity
Status DO 5 bit 5
(S_CPO (Rough match))
Status DO 5 bit 6
(S_MEND (Travel completion))
ON
OFF
ON
OFF
(Note)
Torque limit value2
Positive torque limit value/
Negative torque limit value
Torque limit value2
Positive torque limit value/
Negative torque limit value
Torque limit value2
(Note)
4
4
2
100.00 r/min
0
150.00 r/min
Note. A delay time can be set with [Pr. PT39].