4. PARAMETERS
4 - 39
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
General
purpose
Communication
CP
PS
CP
PS
PT42
*OVM
Digital
override
minimum
multiplication
Set a minimum speed for when the digital override function is enabled.
When you use the digital override function, multiplication can be set with
[Pr. PT42] and [Pr. PT43]. Set this at the same time with [Pr. PT43].
Refer to the following table for how to calculate multiplication value.
Setting "0" will be recognized as "1".
Setting range: 0 to 100
0
[%]
Input device (Note)
Multiplication [%]
OV3
OV2
OV1
OV0
0
0
0
0
Fixed to 100
0
0
0
1
[Pr. PT42]
0
0
1
0
[Pr. PT42] + [Pr. PT43] × 1
0
0
1
1
[Pr. PT42] + [Pr. PT43] × 2
0
1
0
0
[Pr. PT42] + [Pr. PT43] × 3
0
1
0
1
[Pr. PT42] + [Pr. PT43] × 4
0
1
1
0
[Pr. PT42] + [Pr. PT43] × 5
0
1
1
1
[Pr. PT42] + [Pr. PT43] × 6
1
0
0
0
[Pr. PT42] + [Pr. PT43] × 7
1
0
0
1
[Pr. PT42] + [Pr. PT43] × 8
1
0
1
0
[Pr. PT42] + [Pr. PT43] × 9
1
0
1
1
[Pr. PT42] + [Pr. PT43] × 10
1
1
0
0
[Pr. PT42] + [Pr. PT43] × 11
1
1
0
1
[Pr. PT42] + [Pr. PT43] × 12
1
1
1
0
[Pr. PT42] + [Pr. PT43] × 13
1
1
1
1
Fixed to 0
Note. 0: Off
1: On
PT43
*OVS
Digital
override pitch
width
Set an override pitch width for when the digital override function is
enabled.
When you use the digital override function, multiplication can be set with
[Pr. PT42] and [Pr. PT43]. Set this at the same time with [Pr. PT 42].
Refer to the table in [Pr. PT42] for settings.
Setting "0" will be recognized as "1".
Setting range: 0 to 20
0
[%]
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...