12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
12 - 21
Setting
value
Home position return direction
Home position return method
3
Address increasing direction
Method 3
4
Method 4
5
Address decreasing direction
Method 5
6
Method 6
7
Address increasing direction
Method 7
8
Method 8
11
Address decreasing direction
Method 11
12
Method 12
19
Address increasing direction
Method 19
20
Method 20
21
Address decreasing direction
Method 21
22
Method 22
23
Address increasing direction
Method 23
24
Method 24
27
Address decreasing direction
Method 27
28
Method 28
33
Method 33
34
Address increasing direction
Method 34
35
Method 35
37
Method 37 (Data set type)
(b) Select the polarity where the proximity dog is detected with "DOG (Proximity dog) polarity selection"
of [Pr. PT29 Function selection T-3].
With "0" set, a proximity dog is detected when the proximity dog is switched off. With "1" set, a
proximity dog is detected when the proximity dog is switched on.
0 0
0
[Pr. PT29]
DOG (Proximity dog) polarity selection
0: Detection with off
1: Detection with on