7. HOW TO USE THE POINT TABLE
7 - 39
7.7.2 Detailed setting window
The position data range and unit can be changed with the detailed setting in the point table window. For the
position data range and unit in [Pr. PT01] setting, refer to section 7.2.2. To reflect the setting for the
corresponding parameter, click "Update Project" in the point table window.
1)
2)
3)
(1) Command method selection (PT01 *CTY): 1)
Select either the absolute position command method or the incremental value command method.
(2) Others
(a) Feed length multiplication parameter setting STM (PT03 *FTY): 2)
Select a feed length multiplication from 1/10/100/1000.
(b) Position data unit setting (PT01 *CTY): 3)
Select a unit of position data from mm/inch/pulse. When pulse is selected as the unit, the setting of
the feed length multiplication is not reflected.