4. PARAMETERS
4 - 23
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
General
purpose
Communication
CP
PS
CP
PS
PC75
FEWL
Following
error output
level
(Lower four
digits)
Set the output level of the following error output.
Upper and lower are a set.
As the droop pulses condition exceeds the value of [Pr. PC75, Pr. PC76],
when the time set in [Pr. PC77] has elapsed, the "Statusword (Index:
6041h) bit 13 Following error" is turned on. However, setting
"FFFFFFFFh" disables it.
Set the value in hexadecimal.
Setting value:
Upper four
digits
Lower four
digits
[Pr. PC75]
[Pr. PC76]
The unit can be changed to 10
STM
[μm], 10
(STM-4)
[inch], or [pulse] with the
setting of [Pr. PT01].
This parameter corresponds to "Following error window (Index: 6065h)".
When this parameter is mapped to the link device of CC-Link IE Field
Network Basic, do not write the parameter value with MR Configurator2,
as the controller overwrites the parameter value written with MR
Configurator2.
Setting range: 00000000h to FFFFFFFFh
0000h
Refer to
Function
column
for unit.
PC76
FEWH
Following
error output
level
(Upper four
digits)
Set the output level of the following error output.
Upper and lower are a set.
Refer to [Pr. PC75] for details.
The unit can be changed to 10
STM
[μm], 10
(STM-4)
[inch], or [pulse] with the
setting of [Pr. PT01].
0000h
Refer to
Function
column
for unit.
PC77
FEWF
Following
error output
filtering time
Set the time until the following error output is turned on.
As the droop pulses condition exceeds the value of [Pr. PC75, Pr. PC76],
when the time set by this parameter has elapsed, the "Statusword (Index:
6041h) bit 13 Following error" is turned on.
The following error output is disabled when both [Pr. PC75] and [Pr.
PC76] are "FFFFh".
This parameter corresponds to "Following error time out (Index: 6066h)".
When this parameter is mapped to the link device of CC-Link IE Field
Network Basic, do not write the parameter value with MR Configurator2,
as the controller overwrites the parameter value written with MR
Configurator2.
Setting range: 0 to 65535
0000h
Refer to
Function
column
for unit.
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...