4. PARAMETERS
4 - 14
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
General
purpose
Communication
CP
PS
CP
PS
PA06
CMX
Number of
gear teeth on
machine side
Set the number of gear teeth on machine side.
To enable the parameter values in the positioning mode, cycle the power
after setting.
Set the electronic gear within the following range.
(1) 1 ≤ CMX ≤ 16384, 1 ≤ CDV ≤ 16384
(2)
1
9999
≤
CMX
CDV
≤ 9999
(3) CDV × STN ≤ 32767 (STN: Number of stations per rotation [Pr.
PT28])
(4) CMX × CDV ≤ 100000
Setting out of the range will trigger [AL. 37 Parameter error].
When a small value is set to the manual operation mode and the JOG
operation mode, the servo motor cannot be driven at the set servo motor
rotation speed.
Travel distance of 1 station = Pt (servo motor resolution) ×
1
STN
×
CMX
CDV
This parameter corresponds to "Motor revolutions (Index: 6091h, Sub:
1)". When this parameter is mapped to the link device of CC-Link IE Field
Network Basic, do not write the parameter value with MR Configurator2,
as the controller overwrites the parameter value written with MR
Configurator2.
Setting range: 1 to 16777215
1
PA07
CDV
Electronic
gear
denominator
(command
pulse
multiplication
denominator)
Set an electronic gear denominator.
To enable the parameter, select "Electronic gear (0 _ _ _)" of "Electronic
gear selection" in [Pr. PA21].
In the positioning mode, the setting is effective only after rebooting the
power once the parameter values setup is completed.
This parameter corresponds to "Shaft revolutions (Index: 6091h, Sub: 2)".
When this parameter is mapped to the link device of CC-Link IE Field
Network Basic, do not write the parameter value with MR Configurator2,
as the controller overwrites the parameter value written with MR
Configurator2.
Setting range: 1 to 16777215
1
PA07
CDV
Number of
gear teeth on
servo motor
side
Set the number of gear teeth on servo motor side.
To enable the parameter values in the positioning mode, cycle the power
after setting.
Set the electronic gear within the range of [Pr. PA06].
Setting out of the range will trigger [AL. 37 Parameter error].
This parameter corresponds to "Shaft revolutions (Index: 6091h, Sub: 2)".
When this parameter is mapped to the link device of CC-Link IE Field
Network Basic, do not write the parameter value with MR Configurator2,
as the controller overwrites the parameter value written with MR
Configurator2.
Setting range: 1 to 16777215
1
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...