7. HOW TO USE THE POINT TABLE
7 - 36
7.6 Analog override
POINT
When using the analog override in the point table method, enable bit 7 (C_OVR)
of Control DI7 (2D07h).
The following shows the functions in which the analog override cannot be used.
Manual pulse generator operation in the Jog mode
Homing mode (hm)
Test operation mode using MR Configurator2 (positioning operation/JOG
operation)
If the servo motor speed changed by the analog override value exceeds the
maximum speed of the servo motor, the servo motor speed is limited at the
maximum speed of the servo motor.
Override (2DB0h) enables the servo motor speed to be changed. The following table shows signals and
parameters related to the analog override.
Item
Name
Remark
Object/register to be
used
Override
An override value can be set. Set the
override values within the range of
0% to 200%.
Bit 7 (C_OVR) of Control DI7 (2D07h)
Turning C_OVR on enables the
setting of Override.
Select enable/disable of Override (2DB0h) with the bit 7 of Control DI7 (2D07h).
Analog
override
C_OVR
Override
0% to 200%
Servo
motor
Servo amplifier
Position
control
Speed
control
Select a changed value by using C_OVR.
C_OVR (Note)
Speed change value
0
No change
1
The setting value of Override is valid
Note. 0: Off
1: On
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...