7. HOW TO USE THE POINT TABLE
7 - 31
Example 2. Operations when "9" is set in the auxiliary function of point table No. 2
Point table No.
Position data
[10
STM
μm]
Servo motor
speed [r/min]
Acceleration
time constant
[ms]
Deceleration
time constant
[ms]
Dwell [ms]
Auxiliary
function
M code
1
5.00
3000.00
100
150
100
1
5
2
6.00
2000.00
150
200
200
9
10
Operation sequence
1) Starting with point table No. 2
2) Executing point table No. 1 when "9" is set in the auxiliary function of point table No. 2
3) Repeating the above execution in the sequence of 1), 2), 1), 2)
Target point table
Controlword bit 4
(New set-point)
ON
OFF
Point actual value (Note)
6.00
0
6.00
1)
2)
2)
1)
11.00
2
6.00
5.00
17.00
M code actual value (Note)
Servo motor speed
Position address
Forward rotation
0 r/min
Reverse rotation
Point table No. 2
Point table No. 1
Speed
(2000.00)
Speed
(3000.00)
Speed
(2000.00)
Speed
(3000.00)
Note. "Point actual value" and "M code actual value" are not outputted in an automatic continuous operation.