12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
12 - 68
(2) Manual pulse generator operation
(a) Setting
POINT
To enhance noise tolerance, set "_ 2 _ _" in [Pr. PA13] when the command
pulse frequency is 500 kpulses/s or less, or set "_3_ _" in [Pr. PA13] when the
command pulse frequency is 200 kpulses/s or less.
Set input devices and parameters as shown below depending on the intended application. DI0 (Point
table No. selection 1) to DI7 (Point table No. selection 8) are disabled.
Item
Device/parameter to be used
Setting
Manual operation mode
selection
MD0 (Operation mode selection 1)
Switch off MD0.
Manual pulse generator
multiplication
[Pr. PT03]
Set the multiplication factor for the pulses generated
from the manual pulse generator.
For details, refer to (2) (c) in this section.
Servo motor rotation direction [Pr. PA14]
Refer to (2) (b) in this section.
Command input pulse train
input form
[Pr. PA13]
Set "_ _ _ 2" (A/B-phase pulse train).
Pulse train filter selection
[Pr. PA13]
Set other than "_ 0 _ _" and "_ 1 _ _".
(b) Servo motor rotation direction
[Pr. PA14] setting
Servo motor rotation direction
Manual pulse generator: forward
rotation
Manual pulse generator: reverse
rotation
0
CCW rotation
CW rotation
1
CW rotation
CCW rotation
CW
CCW
Forward rotation
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...