12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
12 - 56
3) Operation
Selecting DI0 to DI7 for the point table and switching on ST1 starts positioning to the position
data at the set speed, acceleration time constant and deceleration time constant. At this time,
ST2 (Reverse rotation start) is disabled.
Item
Device to be used
Setting
Automatic operation mode
selection
MD0 (Operation mode selection 1)
Switch on MD0.
Point table selection
DI0 (Point table No. selection 1)
DI1 (Point table No. selection 2)
DI2 (Point table No. selection 3)
DI3 (Point table No. selection 4)
DI4 (Point table No. selection 5)
DI5 (Point table No. selection 6)
DI6 (Point table No. selection 7)
DI7 (Point table No. selection 8)
Refer to section 12.5.2 (1) (b) 2).
Start
ST1 (Forward rotation start)
Switch on ST1 to start.