4. PARAMETERS
4 - 24
4.2.3 I/O setting parameters ([Pr. PD_ _ ])
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
General
purpose
Communication
CP
PS
CP
PS
PD03
*DIA3
Input signal
automatic on
selection 3
Select input devices to turn on automatically.
When setting the "Command interface selection" of [Pr. PN08] to "_ _ _ 1
(Communication interface)", the setting value of this parameter is invalid.
_ _ _ x
(HEX)
_ _ _ x (BIN): MD0 (Operation mode selection 1)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
0h
_ _ x _ (BIN): MD1 (Operation mode selection 2)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
_ _ x _
(HEX)
_ _ _ x (BIN): For manufacturer setting
0h
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): OVR (Analog override selection)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): For manufacturer setting
_ x _ _
(HEX)
_ _ _ x (BIN): For manufacturer setting
0h
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
x _ _ _
(HEX)
_ _ _ x (BIN): For manufacturer setting
0h
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...