7. HOW TO USE THE POINT TABLE
7 - 26
b) Automatic repeat positioning operation by incremental value command method
Example 1. Operations when "10" is set in the auxiliary function of point table No. 4
Point table No.
Position data
[10
STM
μm]
Servo motor
speed [r/min]
Acceleration
time constant
[ms]
Deceleration
time constant
[ms]
Dwell [ms]
Auxiliary
function
M code
1
4.00
1500.00
200
100
150
1
1
2
5.00
3000.00
100
150
100
3
5
3
10.00
2000.00
150
200
200
1
10
4
5.00
1000.00
300
100
150
10
15
Operation sequence
1) Starting with point table No. 2
2) Executing point table No. 3
3) Executing point table No. 4
4) Re-execute point table No. 2 used at start-up when "10" is set in the auxiliary function of
point table No. 4
5) Repeating the above execution in the sequence of 1), 2), 3), 4), 2), 3), 4)
Speed
(3000.00)
Speed
(3000.00)
Target point table
Controlword bit 4
(New set-point)
ON
OFF
Point actual value (Note)
5.00
0
5.00
1)
2)
2)
3)
4)
10.00
15.00
2
5.00
5.00
M code actual value (Note)
Servo motor speed
Position address
Forward rotation
0 r/min
Reverse rotation
Point table No. 2
Point table No. 2
Point table No. 3
Point table No. 3
Point table No. 4
Speed
(2000.00)
Speed
(2000.00)
Speed (1000.00)
Note. "Point actual value" and "M code actual value" are not outputted in an automatic continuous operation.
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...