12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
12 - 33
(2) Timing chart
ON
OFF
MEND
(Travel completion)
ON
OFF
CPO (Rough match)
ON
OFF
ST2
(Reverse rotation start)
MD0
(Operation mode
selection 1)
ON
OFF
ON
OFF
TLC (Limiting torque)
Torque limit value
ZP
(Home position return
completion)
ON
OFF
Servo motor
speed
Forward rotation
Reverse rotation
ST1
(Forward rotation start)
ON
OFF
Acceleration time
constant
Home position return speed
Home position return
position data
3 ms or shorter
5 ms or longer
Stopper
Stopper time
[Pr. PC35]
[Pr. PT11]
[Pr. PC35]
(Note 2)
0 r/min
(Note 1)
Note 1. The following torque limits are enabled at this point.
Input device (0: off, 1: on)
Limit value status
Enabled torque limit value
TL1
TL
0
0
Pr. PT11
0
1
TLA
>
Pr. PT11
Pr. PT11
TLA
<
Pr. PT11
TLA
1
0
Pr. PC35
>
Pr. PT11
Pr. PT11
Pr. PC35
<
Pr. PT11
Pr. PC35
1
1
TLA
>
Pr. PT11
Pr. PT11
TLA
<
Pr. PT11
TLA
2. This turns on when a generated torque reaches a value set with any of [Pr. PA11 Forward rotation torque limit], [Pr. PA12
Reverse rotation torque limit], or [Pr. PC35 Internal torque limit 2].
The setting value of [Pr. PT08 Home position return position data] and [Pr. PT58 Home position return
position data (extension parameter)] is used as the position address at the homing completion.
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...