12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
12 - 86
(2) JOG operation
(a) Setting
Set devices and parameters as shown below depending on the intended application. With this
operation, DI0 (Next station No. selection 1) to DI7 (Next station No. selection 8) are disabled.
Item
Device/parameter to be used
Setting
Selecting indexer method
Control mode selection of [Pr. PA01]
Select "_ _ _ 8" (positioning mode (indexer method)).
Manual operation mode
selection
MD0 (Operation mode selection 1)
Switch on MD0.
MD1 (Operation mode selection 2)
Switch off MD1.
JOG operation selection
[Pr. PT27]
_ _ 1 _: Select JOG operation.
Rotation direction selection
SIG (External limit/Rotation direction decision/
Automatic speed selection)
The rotation direction to a station No. will be as
follows.
Off: Station No. decreasing direction
On: Station No. increasing direction
Servo motor speed
[Pr. PC07]
Set a servo motor speed.
Acceleration time constant/
Deceleration time constant
RT (Second acceleration/deceleration
selection)
1. When RT is turned off
Acceleration time constant: setting value of [Pr.
PC01 Acceleration time constant 1]
Deceleration time constant: setting value of [Pr.
PC02 Deceleration time constant 1]
2. When RT is turned on
Acceleration time constant: setting value of [Pr.
PC30 Acceleration time constant 2]
Deceleration time constant: setting value of [Pr.
PC31 Deceleration time constant 2]
(b) Operation
Turning on ST1 (Forward rotation start) will start rotation to a direction specified with the rotation
direction decision and turning off it will decelerate to a stop regardless of the station position.
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...