11. APPLICATION OF FUNCTIONS
11 - 6
(4) Timing chart
Servo motor
speed
0 r/min
Forward rotation
Reverse rotation
TPR1
(Touch probe 1)
ON
OFF
Controlword bit 4
(New set-point)
ON
OFF
Deceleration time constant (Note)
0.888 ms
Interrupt positioning travel distance
Note. This is the deceleration time constant of point table at the time of start.
The movement examples other than above are as follows.
(a) If the interrupt positioning travel distance is shorter than the travel distance required for the
deceleration, the actual deceleration time constant is shorter than the set time constant.
ON
OFF
ON
OFF
Recalculated deceleration time constant
0.888 ms
Interrupt positioning travel distance
Servo motor
speed
0 r/min
Forward rotation
Reverse rotation
TPR1
(Touch probe 1)
Controlword bit 4
(New set-point)
(b) If the interrupt travel distance is long during acceleration, the servo motor stops with the deceleration
time constant after rotating with the command speed at which TPR1 (Touch probe 1) turned on.
ON
OFF
ON
OFF
0.888 ms
Interrupt positioning travel distance ([Pr. PT30] and [Pr. PT31])
Speed when TPR1 is on
Deceleration time constant (Note)
Servo motor
speed
0 r/min
Forward rotation
Reverse rotation
TPR1
(Touch probe 1)
Controlword bit 4
(New set-point)
Note. This is the deceleration time constant of point table at the time of start.
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...