3. STARTUP
3 - 3
(6) Stop
If any of the following situations occurs, the servo amplifier suspends and stops the operation of the
servo motor.
Turn off the servo-on command after the servo motor has stopped, and then switch the power off.
Refer to section 3.10 in "MR-JE-_C Servo Amplifier Instruction Manual" for the servo motor with an
electromagnetic brake.
Operation/command
Stopping condition
Controller
Servo-off command
The base circuit is shut off, and the servo motor coasts.
Ready-off command
The base circuit is shut off and the dynamic brake operates to bring the servo motor to
a stop.
Quick stop command
The servo motor decelerates to a stop.
Error occurrence (Note 1)
The servo motor decelerates to a stop.
Servo amplifier
Alarm occurrence
The servo motor decelerates to a stop. With some alarms; however, the dynamic
brake operates to stop the servo motor. (Note 2)
EM2 (Forced stop 2) off
The servo motor decelerates to a stop. [AL. E6 Servo forced stop warning] occurs. In
the torque control mode, EM2 functions the same as EM1
LSP (Forward rotation
stroke end) off or LSN
(Reverse rotation stroke
end) off
The servo motor stops immediately and will be servo locked. Operation in the
opposite direction is possible.
Note 1. This is for CC-Link IE Field Network Basic. If an error occurs, RX (n + 3) F is set to "0" (cyclic communication ready turns off).
2. Refer to "MELSERVO-JE Servo Amplifier Instruction Manual (Troubleshooting)" for details of alarms and warnings.
Summary of Contents for MR-JE-C
Page 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Page 37: ...3 STARTUP 3 4 MEMO ...
Page 129: ...6 HOMING MODE 6 36 MEMO ...
Page 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Page 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Page 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Page 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Page 309: ...MEMO ...