12. ABSOLUTE POSITION DETECTION SYSTEM
12 - 4
12.2.2 Using MR-BT6VCASE battery case
POINT
One MR-BT6VCASE holds absolute position data up to eight axes servo motors.
Always install five MR-BAT6V1 batteries to an MR-BT6VCASE.
(1) Configuration diagram
CYC0
Current position
Home position data
LS0
Position data
LS
Detecting the
number of
revolutions
CYC
Detecting the
position within
one revolution
Servo motor
Accumulative revolution counter
(1 pulse/rev)
Within one revolution counter
High speed
serial
communication
Servo amplifier
Servo system controller
MR-BT6VCASE
MR-BAT6V1 × 5
Step-down
circuit
Posi
tion contr
o
l
Speed contr
o
l
( 6 V
3.4 V )
(2) Specification list
Item Description
System
Electronic battery backup type
Maximum revolution range
Home position ± 32767 rev.
(Note 1)
Maximum speed at power
failure [r/min]
Rotary servo motor
6000
(only when acceleration time until 6000 r/min is 0.2 s or more)
Direct drive motor
500
(only when acceleration time until 500 r/min is 0.1 s or more)
(Note 2)
Battery backup time
Rotary servo motor
Approximately 40,000 hours/2 axes or less, 30,000 hours/3 axes, or
10,000 hours/8 axes
(equipment power supply: off, ambient temperature: 20 °C)
Approximately 55,000 hours/2 axes or less, 38,000 hours/3 axes, or
15,000 hours/8 axes
(power-on time ratio: 25%, ambient temperature: 20 °C) (Note 4)
Direct drive motor
Approximately 10,000 hours/2 axes or less, 7,000 hours/3 axes, or
5,000 hours/4 axes
(equipment power supply: off, ambient temperature: 20 °C)
Approximately 15,000 hours/2 axes or less, 13,000 hours/3 axes, or
10,000 hours/4 axes
(power-on time ratio: 25%, ambient temperature: 20 °C) (Note 3)
Note 1. Maximum speed available when the shaft is rotated by external force at the time of power failure or the like. Also, if power is
switched on at the servo motor speed of 3000 r/min or higher, position mismatch may occur due to external force or the like.
2. The data-holding time by the battery using five MR-BAT6V1s. The battery life varies depending on the number of axes
(including axis for using in the incremental system). Replace the batteries within three years since the operation start
regardless of the power supply of the servo amplifier on/off. If the battery is used out of specification, [AL. 25 Absolute position
erased] may occur.
3. The power-on time ratio 25% is equivalent to 8 hours power on for a weekday and off for a weekend.
Summary of Contents for MR-J4W2
Page 9: ...A 8 MEMO ...
Page 17: ...8 MEMO ...
Page 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 95: ...4 STARTUP 4 20 MEMO ...
Page 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Page 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Page 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Page 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Page 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Page 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 521: ...APPENDIX App 38 ...
Page 537: ...MEMO ...
Page 541: ......