6. NORMAL GAIN ADJUSTMENT
6 - 4
6.2.2 Display transition and operation procedure of one-touch tuning
(1) Response mode selection
Select a response mode from 3 modes in the one-touch tuning window of MR Configurator2.
Response mode
Explanation
High mode
This mode is for high rigid system.
Basic mode
This mode is for standard system.
Low mode
This mode is for low rigid system.
Refer to the following table for selecting a response mode.