11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 38
(c) Cable clamp fitting AERSBAN-_SET
Generally, the grounding of the shielded wire may only be connected to the connector's SD terminal.
However, the effect can be increased by directly connecting the cable to an grounding plate as
shown below.
Install the grounding plate near the servo amplifier for the encoder cable. Peel part of the cable
sheath to expose the external conductor, and press that part against the grounding plate with the
cable clamp. If the cable is thin, clamp several cables in a bunch.
The clamp comes as a set with the grounding plate.
[Unit: mm]
Strip the cable sheath of
the clamped area.
cutter
cable
Cable clamp
(A, B)
Cable
Grounding
plate
External conductor
Clamp section diagram
40
Dimensions
[Unit: mm]
Grounding plate
(Note) M4 screw
11
3
6
C
A
6
22
17.5
35
35
7
24
0 -0.
2
B ± 0.3
2-
φ
5 hole
mounting hole
[Unit: mm]
Clamp section diagram
L or less
10
30
24
+ 0.
3
0
Note. Screw hole for grounding. Connect it to the grounding plate of the cabinet.
Model A
B
C
Accessory
fittings
Clamp fitting
L
AERSBAN-DSET
100
86
30
Clamp A: 2 pcs.
A 70
AERSBAN-ESET
70
56
Clamp B: 1 pc.
B 45
Summary of Contents for MR-J4W2
Page 9: ...A 8 MEMO ...
Page 17: ...8 MEMO ...
Page 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 95: ...4 STARTUP 4 20 MEMO ...
Page 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Page 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Page 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Page 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Page 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Page 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 521: ...APPENDIX App 38 ...
Page 537: ...MEMO ...
Page 541: ......