3. SIGNALS AND WIRING
3 - 37
(e) Main circuit power supply off during control circuit power supply on
When the main circuit power supply is turned off, all axes will be the operation status below.
Dynamic brake
Dynamic brake
+ Electromagnetic brake
Electromagnetic brake
Operation delay time of
the electromagnetic brake
MBR
(Electromagnetic
brake interlock)
(Note 2)
Base circuit
Alarm
[AL.10 Undervoltage]
No alarm
Alarm
Servo motor speed
Approx. 10 ms
(Note 1)
ON
OFF
ON
OFF
Main circuit
power supply
ON
OFF
0 r/min
Note 1. Variable according to the operation status.
2.
ON
:
Electromagnetic
brake is not activated.
OFF: Electromagnetic brake is activated.
(f) Ready-off command from controller
It is the same as (1) (f) in this section.
Summary of Contents for MR-J4W2