18. MR-J4W2-0303B6 SERVO AMPLIFIER
18 - 12
(2) Installation of two or more servo amplifiers
POINT
You can install MR-J4W2-0303B6 servo amplifiers without clearances between
them. When closely mounting the servo amplifiers, operate them at the ambient
temperatures of 45
˚
C or lower, or the total effective load ratio of 45 w or lower
for the two axes.
Leave a large clearance between the top of the servo amplifier and the cabinet walls, and install a cooling
fan to prevent the internal temperature of the cabinet from exceeding the environmental conditions.
When mounting the servo amplifiers closely, leave a clearance of 1 mm between the adjacent servo
amplifiers in consideration of mounting tolerances.
100 mm
or more
5 mm
or more
30 mm
or more
30 mm
or more
40 mm or more
Cabinet
Top
Bottom
100 mm or more
1 mm
30 mm
or more
40 mm or more
Cabinet
1 mm
Leaving clearance
Mounting closely
Summary of Contents for MR-J4W2
Page 9: ...A 8 MEMO ...
Page 17: ...8 MEMO ...
Page 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 95: ...4 STARTUP 4 20 MEMO ...
Page 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Page 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Page 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Page 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Page 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Page 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 521: ...APPENDIX App 38 ...
Page 537: ...MEMO ...
Page 541: ......