17. APPLICATION OF FUNCTIONS
17 - 46
(7) Tough drive function
POINT
Set enable/disable of the tough drive function with [Pr. PX25 Tough drive
setting]. (Refer to (2) of this section.)
This function makes the equipment continue operating even under the condition that an alarm occurs.
The vibration tough drive function and instantaneous power failure tough drive function are available with
the J3 extension function.
(a) Vibration tough drive function
This function prevents vibration by resetting a filter instantaneously when machine resonance occurs
due to varied vibration frequency caused by machine aging.
To reset the machine resonance suppression filters with the function, [Pr. PB13 Machine resonance
suppression filter 1] and [Pr. PB15 Machine resonance suppression filter 2] should be set in
advance.
Set [Pr. PB13] and [Pr. PB15] as follows.
1) One-touch tuning execution (Refer to (4) of this section.)
2) Manual setting (Refer to (2) of this section.)
The vibration tough drive function operates when a detected machine resonance frequency is within
±30% for a value set in [Pr. PB13 Machine resonance suppression filter 1] or [Pr. PB15 Machine
resonance suppression filter 2].
To set a detection level of the function, set sensitivity in [Pr. PX26 Vibration tough drive - Oscillation
detection level].
POINT
Resetting [Pr. PB13] and [Pr. PB15] by the vibration tough drive function is
performed constantly. However, the number of write times to the EEPROM is
limited to once per hour.
The vibration tough drive function does not reset [Pr. PX17 Machine resonance
suppression filter 3], [Pr. PX19 Machine resonance suppression filter 4], and [Pr.
PX21 Machine resonance suppression filter 5].
The vibration tough drive function does not detect a vibration of 100 Hz or less.
Summary of Contents for MR-J4W2
Page 9: ...A 8 MEMO ...
Page 17: ...8 MEMO ...
Page 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 95: ...4 STARTUP 4 20 MEMO ...
Page 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Page 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Page 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Page 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Page 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Page 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 521: ...APPENDIX App 38 ...
Page 537: ...MEMO ...
Page 541: ......