5. PARAMETERS
5 - 32
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PB45 CNHF
Table 5.6 Notch depth selection
Refer to Name
and function
column.
Each
Setting value
Depth [dB]
Setting value
Depth [dB]
0
-40.0
8
-6.0
1
-24.1
9
-5.0
2
-18.1
A
-4.1
3
-14.5
B
-3.3
4
-12.0
C
-2.5
5
-10.1
D
-1.8
6
-8.5 E
-1.2
7
-7.2 F
-0.6
PB46
NH3
Machine resonance suppression filter 3
Set the notch frequency of the machine resonance suppression filter 3.
To enable the setting value, select "Enabled (_ _ _ 1)" of "Machine resonance
suppression filter 3 selection" in [Pr. PB47].
4500
[Hz]
10 to
4500
Each
PB47
NHQ3
Notch shape selection 3
Set the shape of the machine resonance suppression filter 3.
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
Machine resonance suppression filter 3 selection
0: Disabled
1: Enabled
0h
_ _ x _
Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _
Notch width selection
0:
α
= 2
1:
α
= 3
2:
α
= 4
3:
α
= 5
0h
x _ _ _
For manufacturer setting
0h
PB48
NH4
Machine resonance suppression filter 4
Set the notch frequency of the machine resonance suppression filter 4.
To enable the setting value, select "Enabled (_ _ _ 1)" of "Machine resonance
suppression filter 4 selection" in [Pr. PB49].
4500
[Hz]
10 to
4500
Each
Summary of Contents for MR-J4W2
Page 9: ...A 8 MEMO ...
Page 17: ...8 MEMO ...
Page 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 95: ...4 STARTUP 4 20 MEMO ...
Page 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Page 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Page 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Page 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Page 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Page 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 521: ...APPENDIX App 38 ...
Page 537: ...MEMO ...
Page 541: ......