5. CiA 402 DRIVE PROFILE
5 - 1
5. CiA 402 DRIVE PROFILE
POINT
Do not give operation commands from two or more master stations to one servo
amplifier. Otherwise, the servo motor may operate unexpectedly.
This chapter describes how to drive a servo motor in the communication. For MR-J4-_GF_(-RJ) servo
amplifier, objects are assigned according to Index of the CiA 402 drive profile. The master station (controller)
can drive the servo motor by accessing the assigned objects.
Refer to chapter 10 for details of the objects.
5.1 State machine control of the servo amplifier
5.1.1 Function description
The servo amplifier status is controlled based on the state machine below. Setting the control command
(6040h) from the master station (controller) changes the status of the slave stations (servo amplifiers). The
current servo amplifier status can be read with the control status (6041h).
Power on
(14)
(13)
Ready-off/Servo-off
(Main circuit charging
completed)
Ready-off/Servo-off
(During main circuit
charging)
Ready-on/Servo-on
(9)
(8)
(12)
(11)
(16)
(H) Fault
Error occurs
Transition by slave
Transition by master
Transition by slave or master
(10)
(2)
(0)
(1)
(7)
(15)
(3)
(6)
(4)
(5)
(G) Fault reaction active
Servo initialization
in process
In wait for forced stop
reset
Forced stop
deceleration
Occurrence of
alarm
In normal drive
(servo-on)
Alarm handling in process
(forced stop deceleration, alarm
history writing, and alarm display
change)
Drive standby
(servo-off)
In wait for main
circuit charging
(ready-off)
(A) Not ready to switch on
(B) Switch on disabled
(C) Ready to switch on
(D) Switched on
(E) Operation enabled
(F) Quick stop active