9. MANUFACTURER FUNCTIONS
9 - 34
(1) Cam axis one cycle current value restoration
POINT
For the cam pattern of to-and-fro control, if no corresponding cam axis current
value per cycle is found, [AL. F6.1 Cam axis one cycle current value restoration
failed] will occur and cam control cannot be executed.
For the cam pattern of feed control, if no corresponding cam axis current value
per cycle is found, the cam standard position will automatically change and the
value will be searched again.
If the cam resolution of the cam used is large, search processing at cam control
switching may take a long time.
When bit 5 of Control DI2 (2D02h) turns on, the control is switched to the cam control, restoring the
"Cam axis current value per cycle" based on the "Cam standard position" and the "Cam axis feed
current value". Set the "Cam standard position" used for the restoration with cam control data. The feed
current value at cam control switching is used as "Cam axis feed current value".
To restore the cam axis current value per cycle, search for a corresponding value "Cam axis current
value per cycle" from the beginning to the end of the cam pattern.
Set the starting point for searching the cam pattern with "[Cam control data No. 7 Cam axis current value
per cycle initial setting value]". (It is also possible to search from the return path in the cam pattern of to-
and-fro control.)
Searching for the cam pattern
(It is also possible to search from a value in the
middle of the cam axis one cycle current value).
Cam axis one cycle current value
Cam axis feed current value
Cam standard position