9. MANUFACTURER FUNCTIONS
9 - 31
(1) Instantaneous stop
The operation stops without deceleration. The servo amplifier immediately stops the command.
Cam axis one cycle current value
Feed current value
Feed speed
t
t
t
Instantaneous stop
(2) Deceleration stop
The output axis decelerates to stop according to [Pr. PC51 Forced stop deceleration time constant].
After a deceleration stop starts, the cam axis current value per cycle and feed current value are not
updated. The path of the feed current value is drawn regardless of the cam control and the servo motor
stops.
Decelerate the input axis to stop when decelerating the output axis to stop in synchronization with the
input axis.
t
t
t
Cam axis one cycle current value
Feed current value
Feed speed
Deceleration to a stop
When a positioning command (internal command) is used for the input axis, inputting a temporary stop
or switching the operation mode decelerates the input axis to stop. The output axis stops in
synchronization with the input axis. Therefore, the synchronous relation between the input and output
axes are maintained and the cam control does not stop.
When the control mode is switched to the home position return mode (hm), the cam control stops.