10. OBJECT DICTIONARY
10 - 20
10.3.3 Control DI (2D01h to 2D0Ah)
Index
Sub
Index
Name Data
Type
Access
2D01h
to
2D0Ah
0
Control DI1 to Control DI10
U16
rw
The on/off status of input device can be read.
The on/off status of input device can also be set.
The following table lists readable and writable input devices.
Bit definition of control DI1
Bit Symbol
Description
0
The value at reading is undefined. Set "0" when writing.
1
2
3
4 C_CDP
Gain switching
Turning C_CDP on switches the values of [Pr. PB29] to [Pr. PB36] and [Pr. PB56] to [Pr. PB60] as the load to
motor inertia ratio and gain values.
5 C_CLD
Fully closed loop control switching
Use this bit when the semi closed loop control/fully closed loop control switching is enabled with [Pr. PE01].
Turn off C_CLD to select the semi closed loop control, and turn on C_CLD to select the fully closed loop
control.
6
The value at reading is undefined. Set "0" when writing.
7
8
9
10
11
12
13
14
15