9. MANUFACTURER FUNCTIONS
9 - 33
9.5.13 Cam axis position at cam control switching
The cam axis position is determined by the positional relationship of three values of "Cam axis current value
per cycle", "Cam axis standard position", and "Cam axis feed current value". When the control has been
switched to the cam control (bit 5 of Control DI2 (2D02h) is on), defining the positions of two of these values
restores the position of the remaining one value.
Cam axis one cycle current value
Cam axis feed current value
Cam standard position
The following table lists the parameters required to be set for the cam axis position restoration. Refer to
section 9.5.7 (4) for the settings.
Cam axis position
restoration target
([Cam control data
No. 2])
Cam standard
position setting
method ([Cam
control data No. 3])
Cam standard
position initial
setting value ([Cam
control data No. 6])
Cam axis current
value per cycle
setting method
([Cam control data
No. 4])
Cam axis current
value per cycle initial
setting value ([Cam
control data No. 7])
Restoration
processing details
0: Cam axis one
cycle current
value restoration
(Note)
(Used as the search
starting point of cam
pattern.)
"Cam axis current
value per cycle" is
restored based on
"Cam standard
position" and "Cam
axis feed current
value".
1: Cam standard
position
restoration
(Note)
"Cam standard
position" is restored
based on "Cam axis
current value per
cycle" and "Cam axis
feed current value".
2: Cam axis feed
current value
restoration
(Note)
(Note)
"Cam axis feed
current value" is
restored based on
"Cam axis current
value per cycle" and
"Cam standard
position".
: Setting is required.
Note. Set this parameter when [Cam control data No. 3] is set to "1".
Summary of Contents for MR-J4-_GF
Page 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Page 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Page 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Page 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Page 271: ...MEMO ...