7. PARAMETERS
7 - 27
7.2.5 Network setting parameters ([Pr. PN_ _ ])
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
C
P
P
S
PN02
CERT
Communicati
on error
detection time
Set the time until [AL. 86.1 Network communication error 1] is detected.
When "0" is set, the detection time becomes 1000 [ms].
Setting range: 0 to 1000
0
[ms]
PN10
EIC
Ethernet
communicatio
n time-out
selection
Set the time until [AL. 86.4 Network communication error 4] is detected.
Setting "0" will disable the detection of [AL. 86.4 Network communication error 4].
This parameter is enabled with SLMP.
Detection of [AL. 86.4] starts when SLMP is received for the first time. When an alarm is
detected and then reset, the detection stops and will restart upon receipt of the next
SLMP.
Setting range: 0 to 60
0
[s]
PN11
**IPADA
IP address
setting A
_ _ x x IP address setting 2
Set the 2nd octet of the IP address in hexadecimal.
Set the IP address assigned by the network administrator.
When the parameter is set to "_ _ 0 0", the 2nd octet is "168".
When SLMP command (IPAddressSet) is received, the setting of the 2nd octet will be
written to this digit.
Refer to table 7.1 for the relation between the setting value of the rotary switch and the
parameter setting value.
Setting range: 00h to FFh
00h
x x _ _ IP address setting 1
Set the 1st octet of the IP address in hexadecimal.
Set the IP address assigned by the network administrator.
When the parameter is set to "0 0 _ _", the 1st octet is "192".
When SLMP command (IPAddressSet) is received, the setting of the 1st octet will be
written to this digit.
Refer to table 7.1 for the relation between the setting value of the rotary switch and the
parameter setting value.
Setting range: 00h to FFh
00h
Table 7.1 Relation between IP address setting and rotary switch
Rotary
switches
(SW2/SW3)
IP address
00h
1st octet
The setting value of [Pr. PN11 (x x _ _)] is used.
2nd octet
The setting value of [Pr. PN11 (_ _ x x)] is used.
3rd octet
The setting value of [Pr. PN12 (x x _ _)] is used.
4th octet
The setting value of [Pr. PN12 (_ _ x x)] is used.
01h to FFh
1st octet
The setting value of [Pr. PN11 (x x _ _)] is used.
2nd octet
The setting value of [Pr. PN11 (_ _ x x)] is used.
3rd octet
The setting value of [Pr. PN12 (x x _ _)] is used.
4th octet
The setting value of the rotary switches (SW2/SW3) is used.