6. SERVO MOTOR DRIVING
6 - 62
2) Incremental value command method ([Pr. PT01] = _ _ _ 1)
Setting "8" to the auxiliary function performs automatic continuous operation or varying-speed
operation until that point table, and after the completion of positioning, performs the operation
again from the operation pattern of the set point table.
Setting "9" to the auxiliary function performs an automatic continuous operation or a varying-
speed operation until that point table, and after the completion of positioning, performs the
operation again from the operation pattern of point table No. 1.
b) Automatic repeat positioning operation by incremental value command method
Example 1. Operations when "8" is set to the auxiliary function of point table No. 3
Point table
No.
Position data
[10
STM
μ
m]
Servo motor
speed [r/min]
Acceleration
time constant
[ms]
Deceleration
time constant
[ms]
Dwell [ms]
Auxiliary
function
1 4.00
1500.00
200 100
150 1
2 5.00
3000.00
100 150
100 1
3 6.00
2000.00
150 200 200 8
Operation sequence
1) Starting with point table No. 2
2) Executing point table No. 3
3) Executing again point table No. 2 used at start-up when "8" is set to the auxiliary function of
point table No. 3
4) Repeating the above execution in the sequence of 1), 2), 3), 2), 3)
Servo motor speed
Forward rotation
0 r/min
Reverse rotation
Position address
Target point table
Controlword bit 4
(New set-point)
ON
OFF
Point actual value
(Note)
Speed
(3000.00)
Point table No. 2
Speed
(2000.00)
5.00
0
5.00
11.00
2
5.00
1)
2)
2)
3)
6.00
16.00
Speed
(3000.00)
Speed
(2000.00)
Point table No. 3
Note. "Point actual value" is not outputted in an automatic continuous operation.