9. MANUFACTURER FUNCTIONS
9 - 23
(a) Relation among the main shaft input axis, position data unit, and feed length multiplication setting
The parameters used to set the position data unit and feed length multiplication differ depending on
the setting of [Cam control data No. 30 Main shaft input axis selection].
Item
Main shaft input axis selection ([Cam control data No. 30])
0
(Disabled)
1
(Servo input axis)
2
(Synchronous encoder axis)
Main shaft current value per cycle setting
method
([Cam control data No. 5])
Unit
[Pr. PT01]
[Pr. PT01]
[Cam control data No. 14]
Multipli
cation
[Pr. PT03]
[Pr. PT03]
Cam standard position initial setting value
([Cam control data No. 6])
Unit
[Pr. PT01]
[Pr. PT01]
[Pr. PT01]
Multipli
cation
[Pr. PT03]
[Pr. PT03]
[Pr. PT03]
Cam axis current value per cycle initial setting
value
([Cam control data No. 7])
Unit
[Pr. PT01]
[Pr. PT01]
[Cam control data No. 14]
Multipli
cation
[Pr. PT03]
[Pr. PT03]
Synchronous encoder axis unit conversion
numerator
([Cam control data No. 15])
Unit
[Pr. PT01]
[Pr. PT01]
Multipli
cation
[Pr. PT03]
[Pr. PT03]
Synchronous encoder axis unit conversion
denominator
([Cam control data No. 16])
Unit
[Pr. PT01]
[Pr. PT01]
Multipli
cation
[Pr. PT03]
[Pr. PT03]
Cam axis length per cycle
([Cam control data No. 48])
Unit
[Pr. PT01]
[Pr. PT01]
Multipli
cation
[Pr. PT03]
[Pr. PT03]
Cam stroke amount
([Cam control data No. 51])
Unit
[Pr. PT01]
[Pr. PT01]
[Pr. PT01]
Multipli
cation
[Pr. PT03]
[Pr. PT03]
[Pr. PT03]
Cam position compensation amount
([Cam control data No. 60])
Unit
[Pr. PT01]
[Pr. PT01]
[Cam control data No. 14]
Multipli
cation
[Pr. PT03]
[Pr. PT03]
(b) Synchronous encoder axis unit conversion gear setting
The input travel distance of the synchronous encoder is in encoder pulse units. You can convert the
unit into a desired unit by setting [Cam control data No. 15 Synchronous encoder axis unit
conversion: Numerator] and [Cam control data No. 16 Synchronous encoder axis unit conversion:
Denominator].
Set [Cam control data No. 15] and [Cam control data No. 16] according to the machine to be
controlled.
[Cam control data No. 15]
[Cam control data No. 16]
Synchronous encoder
axis travel distance
(after unit conversion)
=
Synchronous encoder
input travel distance
(encoder pulse unit)
×
The travel distance in numbers of pulses set in [Cam control data No. 16] is set in [Cam control data
No. 15] in synchronous encoder axis position units.
Set [Cam control data No. 16] in encoder pulse units of the synchronous encoder.