10. OBJECT DICTIONARY
10 - 34
10.4.3 Control mode display (6061h)
Index
Sub
Index
Name Data
Type
Access
6061h
0
Modes of operation Display
I8
ro
The current control mode can be read.
The setting value of each control mode is as follows.
Control mode
Setting
value
Homing mode
6
Jog mode
-100
Point table mode
-101
Indexer mode
-103
10.4.4 Software Position Limit (607Dh)
Index
Sub
Index
Name Data
Type
Access
607Dh
0
Software Position Limit
Number of entries
U8
ro
1
Min Position Limit
I32
rw
2
Max Position Limit
I32
The current software limit setting can be read.
At this time, "02h" is returned to Number of entries.
The stroke limit value in the reverse direction is returned to Min Position Limit in units of commands.
The stroke limit value in the forward direction is returned to Max Position Limit in units of commands.
The current software limit setting can also be written.
At this time, set "02h" for Number of entries.
Set the stroke limit value in the reverse direction in Min Position Limit in units of commands.
Set the stroke limit value in the forward direction in Max Position Limit in units of commands.
Setting the same value in Min Position Limit and Max Position Limit disables the software limit.