7. PARAMETERS
7 - 19
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
C
P
P
S
PT15
LMPL
Software limit
+
(lower four
digits)
Set an address increasing side of the software stroke limit.
The combination of the upper and lower digits makes one address.
Set an address in hexadecimal.
Setting address:
Upper four
digits
Lower four
digits
[Pr. PT15]
[Pr. PT16]
Setting the same value in "Software limit -" disables the software limit.
When setting this parameter with MR Configurator2, change the status to servo-off or the
mode to the home position return mode.
The unit can be changed to 10
STM
[
μ
m], 10
(STM-4)
[inch], or [pulse] with the setting of [Pr.
PT01].
Setting range: 0000h 0000h to FFFFh FFFFh
0000h
Refer to
Function
column
for unit.
PT16
LMPH
Software limit
+
(upper four
digits)
0000h
Refer to
Function
column
for unit.
PT17
LMNL
Software limit
-
(lower four
digits)
Set an address decreasing side of the software stroke limit.
The combination of the upper and lower digits makes one address.
Set an address in hexadecimal.
Setting address:
Upper four
digits
Lower four
digits
[Pr. PT17]
[Pr. PT18]
Setting the same value in "Software limit +" will disable the software stroke limit.
When setting this parameter with MR Configurator2, change the status to servo-off or the
mode to the home position return mode.
The unit can be changed to 10
STM
[
μ
m], 10
(STM-4)
[inch], or [pulse] with the setting of [Pr.
PT01].
Setting range: 0000h 0000h to FFFFh FFFFh
0000h
Refer to
Function
column
for unit.
PT18
LMNH
Software limit
-
(upper four
digits)
0000h
Refer to
Function
column
for unit.
PT19
*LPPL
Position
range output
a
(lower four
digits)
Set an address increasing side of the position range output address.
The combination of the upper and lower digits makes one address. Using [Pr. PT19] to
[Pr. PT22], set a range in which Index 2D17h Status DO7 bit2 (Position range) turns on.
Setting address:
[Pr. PT19]
[Pr. PT20]
Upper four
digits
Lower four
digits
The unit can be changed to 10
STM
[
μ
m], 10
(STM-4)
[inch], or [pulse] with the setting of [Pr.
PT01].
Setting range: 0000h 0000h to FFFFh FFFFh
0000h
Refer to
Function
column
for unit.
PT20
*LPPH
Position
range output
a
(upper four
digits)
0000h
Refer to
Function
column
for unit.