10. OBJECT DICTIONARY
10 - 1
10. OBJECT DICTIONARY
Each data such as control parameters, command values, and feedback values is handled as an object
composed of an address, object name, data type, access rule, and other elements. The object data can be
exchanged between the master station (controller) and the slave stations (servo amplifiers). The aggregate
of these objects is called object dictionary.
The following is shown in the "Access" column.
"ro": Only reading is available.
"wo": Only writing is available.
"rw": Reading and writing are available.
10.1 Object dictionary list
Index
Sub
Index
Name and function
Data
Type
Access
Variable
mapping
Default
Range
Units
EEP-
ROM
Param
eter
1000 0 Device
Type
This displays the servo drive defined with the CiA
402 profile.
U32 ro
Impossible
00020192h 00020192h
(fixed)
1008
0
Manufacturer Device Name
The model name of the servo amplifier is returned.
VISIBLE
STRING
ro
Impossible
1009
0
Manufacturer Hardware Version
The hardware version of the network module is
returned.
VISIBLE
STRING
ro
Impossible
100A
0
Manufacturer Software Version
The software version of the servo amplifier is
returned.
VISIBLE
STRING
ro
Impossible
1010 0 Store
parameters
The number of entries is returned.
U8 ro
Impossible
1 01h
1
Save all parameters
[Writing]
Writing "save" (= 65766173h) saves all the objects
which can be stored in the EEP-ROM.
[Reading]
Bit 0: 0: The parameter cannot be saved with the
command. (A parameter is being saved.)
1: The parameter can be saved with the
command. (No parameter is being saved.)
Bit 1: 0: The parameter is not automatically saved.
U32 rw
Impossible
00000001h
1011
0
Restore default parameters
The number of entries is returned.
U8 ro
Impossible
1 01h
(fixed)
1
Restore all default parameters
The servo amplifier parameters can be rewritten to
the factory setting.
To initialize the parameters, write "64616F6Ch" (=
reverse order of ASCII code of "load") to Restore
all default parameters (1011h: 1), and then cycle
the power.
U32 rw
Impossible
00000001h